我遇到了一个问题,我的主键序列与我的表行不同步。

也就是说,当我插入一个新行时,我得到一个重复的键错误,因为在串行数据类型中隐含的序列返回一个已经存在的数字。

这似乎是由于导入/恢复没有正确地维护序列造成的。


当前回答

重置所有公共序列

CREATE OR REPLACE FUNCTION "reset_sequence" (tablename text) RETURNS "pg_catalog"."void" AS 
$body$  
  DECLARE 
  BEGIN 
  EXECUTE 'SELECT setval( ''' 
  || tablename  
  || '_id_seq'', ' 
  || '(SELECT id + 1 FROM "' 
  || tablename  
  || '" ORDER BY id DESC LIMIT 1), false)';  
  END;  
$body$  LANGUAGE 'plpgsql';

select sequence_name, reset_sequence(split_part(sequence_name, '_id_seq',1)) from information_schema.sequences
        where sequence_schema='public';

其他回答

丑陋的黑客修复它使用一些贝壳魔法,不是一个伟大的解决方案,但可能会激励其他人有类似的问题:)

pg_dump -s <DATABASE> | grep 'CREATE TABLE' | awk '{print "SELECT setval(#" $3 "_id_seq#, (SELECT MAX(id) FROM " $3 "));"}' | sed "s/#/'/g" | psql <DATABASE> -f -

此命令仅用于更改postgresql中自动生成的键序列值

ALTER SEQUENCE "your_sequence_name" RESTART WITH 0;

在零的地方,你可以放任何你想重新启动序列的数字。

默认序列名为“TableName_FieldName_seq”。例如,如果您的表名是“MyTable”,字段名是“MyID”,那么序列名将是“MyTable_MyID_seq”。

这个答案与@murugesanponappan的答案相同,但在他的解决方案中有一个语法错误。在alter命令中不能使用sub query (select max()…)所以要么你必须使用固定的数值,要么你需要使用变量来代替子查询。

这里有很多很好的答案。在重新加载Django数据库后,我也有同样的需求。

但我需要:

All in one功能 可以一次修复一个或多个模式吗 可以修复所有或只是一个表的时间 还想要一个很好的方式来确切地看到什么改变了,或没有改变

这似乎与最初的要求非常相似。 多亏了Baldiry和Mauro让我找到了正确的方向。

drop function IF EXISTS reset_sequences(text[], text) RESTRICT;
CREATE OR REPLACE FUNCTION reset_sequences(
    in_schema_name_list text[] = '{"django", "dbaas", "metrics", "monitor", "runner", "db_counts"}',
    in_table_name text = '%') RETURNS text[] as
$body$
  DECLARE changed_seqs text[];
  DECLARE sequence_defs RECORD; c integer ;
  BEGIN
    FOR sequence_defs IN
        select
          DISTINCT(ccu.table_name) as table_name,
          ccu.column_name as column_name,
          replace(replace(c.column_default,'''::regclass)',''),'nextval(''','') as sequence_name
          from information_schema.constraint_column_usage ccu,
               information_schema.columns c
          where ccu.table_schema = ANY(in_schema_name_list)
            and ccu.table_schema = c.table_schema
            AND c.table_name = ccu.table_name
            and c.table_name like in_table_name
            AND ccu.column_name = c.column_name
            AND c.column_default is not null
          ORDER BY sequence_name
   LOOP
      EXECUTE 'select max(' || sequence_defs.column_name || ') from ' || sequence_defs.table_name INTO c;
      IF c is null THEN c = 1; else c = c + 1; END IF;
      EXECUTE 'alter sequence ' || sequence_defs.sequence_name || ' restart  with ' || c;
      changed_seqs = array_append(changed_seqs, 'alter sequence ' || sequence_defs.sequence_name || ' restart with ' || c);
   END LOOP;
   changed_seqs = array_append(changed_seqs, 'Done');

   RETURN changed_seqs;
END
$body$ LANGUAGE plpgsql;

然后执行并查看更改运行:

select *
from unnest(reset_sequences('{"django", "dbaas", "metrics", "monitor", "runner", "db_counts"}'));

返回

activity_id_seq                          restart at 22
api_connection_info_id_seq               restart at 4
api_user_id_seq                          restart at 1
application_contact_id_seq               restart at 20

如果您在加载自定义SQL数据进行初始化时看到此错误,另一种避免此错误的方法是:

而不是写:

INSERT INTO book (id, name, price) VALUES (1 , 'Alchemist' , 10),

从初始数据中删除id(主键)

INSERT INTO book (name, price) VALUES ('Alchemist' , 10),

这使Postgres序列保持同步!

选择setval…使JDBC变得无聊,所以这里有一种与java兼容的方法:

-- work around JDBC 'A result was returned when none was expected.'
-- fix broken nextval due to poorly written 20140320100000_CreateAdminUserRoleTables.sql
DO 'BEGIN PERFORM setval(pg_get_serial_sequence(''admin_user_role_groups'', ''id''), 1 + COALESCE(MAX(id), 0), FALSE) FROM admin_user_role_groups; END;';