我使用实体框架,SQL Server 2000, Visual Studio 2008和企业库开发了一个应用程序。

它在本地工作得非常好,但是当我将项目部署到我们的测试环境时,我得到了以下错误:

Unable to load one or more of the requested types. Retrieve the LoaderExceptions property for more information Stack trace: at System.Reflection.Module._GetTypesInternal(StackCrawlMark& stackMark) at System.Reflection.Assembly.GetTypes() at System.Data.Metadata.Edm.ObjectItemCollection.AssemblyCacheEntry.LoadTypesFromAssembly(LoadingContext context) at System.Data.Metadata.Edm.ObjectItemCollection.AssemblyCacheEntry.InternalLoadAssemblyFromCache(LoadingContext context) at System.Data.Metadata.Edm.ObjectItemCollection.AssemblyCacheEntry.LoadAssemblyFromCache(Assembly assembly, Boolean loadReferencedAssemblies, Dictionary2 knownAssemblies, Dictionary2& typesInLoading, List`1& errors) at System.Data.Metadata.Edm.ObjectItemCollection.LoadAssemblyFromCache(ObjectItemCollection objectItemCollection, Assembly assembly, Boolean loadReferencedAssemblies) at System.Data.Metadata.Edm.ObjectItemCollection.LoadAssemblyForType(Type type) at System.Data.Metadata.Edm.MetadataWorkspace.LoadAssemblyForType(Type type, Assembly callingAssembly) at System.Data.Objects.ObjectContext.CreateQuery[T](String queryString, ObjectParameter[] parameters)

实体框架似乎有问题,任何线索如何修复它?


当前回答

我在编译Visual Studio包(VSPackage)时报告了相同的错误消息。编译整个解决方案,当CreatePkgDef创建包时抛出错误。话虽如此,很明显,我无法捕获loaderexception,因为它不是我的应用程序抛出的,而是微软自己的工具。(虽然我对CreatePkgDef的混乱负责。)

在我的情况下,根本原因是我的解决方案创建了一个MyDll.dll,已经注册到GAC(他们是不同的),所以CreatePgkDef混淆了使用哪个,它决定只是抛出一个错误,这并没有真正的帮助。GAC中的MyDll.dll是由相同产品的安装程序注册的(显然是较早的版本,内容略有不同)。

如何解决

Preferred way: Make sure you use the correct version of MyDll.dll When compiling your project make sure you use a different version number than you used in the previous version located in the GAC. Make sure the following attributes are correct: [assembly: AssemblyVersion("1.0.0.1")] // Assuming the old DLL file was versioned 1.0.0.0 [assembly: AssemblyFileVersion("1.0.0.1")] // Assuming the old DLL file was versioned 1.0.0.0 If needed, specify the fully qualified assembly name (for example, "MyDll.dll, Version=1.0.0.1, Culture=neutral, PublicKeyToken=1234567890abcdef") when you reference it in your other projects. If the above failed: You can uninstall the old MyDll.dll from GAC How to Uninstall an Assembly from the GAC Uninstall the application that includes MyDll.dll

更改AssemblyVersion对我来说已经足够好了。:)

我希望这对你们有帮助。

其他回答

以防其他答案都帮不了你:

当我遇到这个问题时,原来我的Windows服务是为x64平台构建的,而我无意中运行了32位版本的InstallUtil.exe。因此,请确保您使用的InstallUtil版本适合您所构建的平台。

在配置文件中将32位IIS模式设置为true,调试模式设置为true,删除临时目录并重置IIS可以暂时修复问题,一段时间后它会恢复。

如果部署到IIS,请确保允许在IIS上使用32位应用程序。您可以在当前应用程序池的设置上定义这一点。

我改变了引用的特定版本属性为假,这有助于。

正如之前所提到的,通常情况下,组装不存在。

要确切地知道您丢失了什么程序集,请附加调试器,设置断点,当您看到异常对象时,钻到'LoaderExceptions'属性。丢失的程序集应该在那里。

希望能有所帮助!