好的,我有:

Visual Studio 2010 RC, W7 x64,启动了一个新的项目类型的Silverlight应用程序。在ASP中托管Silverlight应用程序。NET Web应用程序项目。Silverlight 3.0版。 添加了一个LinqToSQL类,一个WCF服务,一个Winform测试应用程序(解决方案中的项目)和一些类(也作为解决方案中的项目)。

昨天,我突然得到了“断点当前不会被击中”。本文档未加载任何符号。'消息出现在IDE中,但它只影响Web Appliaction,我可以调试Silverlight和Winform应用程序。

我尝试/做了什么来摆脱这条信息:

Reset Visual Studio Settings removed all files in every \Temporary ASP.NET Files Folder (there is one for each 32bit/64bit and for Framework 2.0 and 4.0) tried to debug using Visual Studio Integrated Web server - normally I use IIS, in the project output of the solution I deleted every obj and bin folders in every project folder created a new solution and added all the projects to this new solution deleted the solution suo file created a new ASP.NET Web Application to test if it is a VS-installation issue => I can debug this new project/solution rebooted the machine several times repaired the vs.net installation did an IISReset removed the Web App from IIS used the Create Virtual Directory Button under Project Properties of the Web App to create a new Web App in IIS changed the Framework Version of every project from 3.5 to 4.0 Opened the Solution on my second machine => same behavior crawled Microsoft Connect for bugs / similar issues SPENT 7 HOURS.

这是我人生中第二次这样了。上次我通过删除临时ASP解决了这个问题。NET文件文件夹,但这次我需要你的帮助。


当前回答

一种可能的情况是,如果你的ASP项目在应用程序中引用一些代码(而不是一个dll),那么这些符号将不会被加载。

在调试代码时,我不得不暂时将引用的应用程序更改为类库。

其他回答

If you are having problems with Silverlight projects the solution can be fairly simple. According to my experience in many cases debugging symbols are not being loaded due to the new ".xap" files not being deployed to temporary folder (either internal VS Cassini or IIS Express). In this situation full rebuilds or resetting VS settings won't help. The easiest solution is just to delete temporary internet files within your browser. If you are using IE for Silverlight development and testing I would recommend switching on "Delete browsing history on exit" option in order not to have such issues in the future.

右键单击解决方案——> Properties

查看公共属性—>启动项目

选择多个启动项目

在需要调试的项目上选择“启动操作”。

尝试将Silverlight Application Project设置为启动项目:右键单击Project -> '设置为启动项目。然后按F5,看看你是否能捕捉到断点…

每次对silverlight应用程序进行更改时,尝试删除浏览器中的浏览/临时数据

我有一个类似的问题,除了我的问题是愚蠢的-我有2个内置的web服务器运行在2个不同的端口和我的项目->属性-> web ->“启动URL”指向一个固定的端口,但web应用程序实际上并没有在该端口下运行。所以我的浏览器被重定向到“开始URL”,它指向1539,但代码/调试实例在端口50803下运行。

我将内置web服务器更改为在固定端口下运行,并调整了我的“起始URL”以使用该端口。 项目->属性-> web ->“服务器”部分->“使用Visual Studio开发服务器”->特定端口

请检查承载silverlight xap的Web (Asp.Net)项目的Web属性。 去Web项目托管你的silverlight xap ->属性-> Web ->调试器部分->确保选中了silverlight复选框。