我们已经使用WiX有一段时间了,尽管人们对它的易用性有一些抱怨,但它运行得相当不错。我想要的是有用的建议:

设置WiX项目(布局、引用、文件模式) 将WiX集成到解决方案中,并构建/发布流程 为新的安装和升级配置安装程序 任何你想分享的好的WiX技巧


当前回答

设置IIS enable32BitAppOnWin64标志http://trycatchfail.com/blog/post/WiX-Snippet-change-enable32BitAppOnWin64.aspx

<InstallExecuteSequence>
   <RemoveExistingProducts After="InstallFinalize" />
   <Custom Action="ConfigureAppPool" After="InstallFinalize" >
     <![CDATA[NOT Installed AND VersionNT64 >= 600]]>         
   </Custom>
</InstallExecuteSequence>

<CustomAction Id="ConfigureAppPool" Return="check" Directory="TARGETDIR" ExeCommand="[SystemFolder]inetsrv\appcmd set apppool /apppool.name:[APPPOOLNAME] /enable32BitAppOnWin64:false" />

其他回答

包括COM对象:

Heat生成所有(如果不是全部)注册表项和它们所需的其他配置。喜乐!

包括托管COM对象(又名。net或c# COM对象)

在托管COM对象上使用heat将为您提供一个几乎完整的wix文档。

If you don't need the library available in the GAC (ie, globally available: MOST of the time you do not need this with your .NET assemblies anyway - you've probably done something wrong at this point if it's not intended to be a shared library) you will want to make sure to update the CodeBase registry key to be set to [#ComponentName]. If you ARE planning on installing it to the GAC (eg, you've made some new awesome common library that everyone will want to use) you must remove this entry, and add two new attributes to the File element: Assembly and KeyPath. Assembly should be set to ".net" and KeyPath should be set to "yes".

然而,某些环境(特别是带有托管内存的环境,如脚本语言)也需要访问Typelib。确保在你的打字单上运行热度并包括它。Heat将生成所有需要的注册表项。多酷啊!

从Wix3.0及更高版本打印EULA

1)当你编译你的wix源代码时,light.exe必须在命令行引用WixUIExtension.dll。为此使用命令行开关-ext。

2)如果当你在WixUIExtension.dll中添加引用时,你的项目编译失败,这很可能是因为对话框id的冲突,即你的项目使用了与WixUIExtension.dll中一些标准对话框相同的对话框id,给你的对话框提供不同的id。这是一个很普遍的问题。

3)你的许可对话框必须有id为“LicenseText”的ScrollableText控件。Wix在打印时搜索该控件的名称。

<Control Id="LicenseText" Type="ScrollableText" X="20" Y="60" Width="330" Height="160" Sunken="yes" TabSkip="no">
    <Text SourceFile="License.rtf" />
</Control>

以及指向自定义动作的PushButton

<Control Type="PushButton" Id="PrintButton" Width="57" Height="17" X="19" Y="244" Text="Print">
    <Publish Event="DoAction" Value="PrintEula">1</Publish>
</Control>

4)使用Id="PrintEula"定义CustomAction,如下所示:

<CustomAction Id="PrintEula" BinaryKey="WixUIWixca" DllEntry="PrintEula" Return="ignore" Execute="immediate" />

注意:BinaryKey在Wix3.0和Wix2.0中是不同的,必须准确地为“WixUIWixca”(区分大小写)。

当用户按下按钮时,他/她将出现标准的选择打印机对话框,并能够从那里打印。

修复ProgressDlg,使其正确显示。

我将安装程序的字体大小从8增加到10,以使字体在高分辨率显示器上更人性化、更实用。我用这个XML魔法做到这一点:

<UI Id="MyCustomUI">
  <TextStyle Id="WixUI_Font_Normal" FaceName="Tahoma" Size="10" />
  <TextStyle Id="WixUI_Font_Big"    FaceName="Tahoma" Size="12" />
  <TextStyle Id="WixUI_Font_Bigger" FaceName="Tahoma" Size="14" />
  <TextStyle Id="WixUI_Font_Title"  FaceName="Tahoma" Size="12" Bold="yes" />

  <Property Id="DefaultUIFont" Value="WixUI_Font_Normal" />
</UI>

但这意味着ProgressDlg将无法正常显示。这是一个显示安装进度的程序,就在最后。ActionText被剪切,因此g和j等字母的下移不显示。在后处理Javascript中,通过调整Progressdialog中各种控件的大小和位置来解决这个问题。生成MSI后运行这个脚本:

var msiOpenDatabaseModeTransact = 1;
var filespec = WScript.Arguments(0);
var installer = new ActiveXObject("WindowsInstaller.Installer");
var database = installer.OpenDatabase(filespec, msiOpenDatabaseModeTransact);

// The text on the exit dialog is too close to the title.  This 
// step moves the text down from Y=70 to Y=90, about one line. 
sql = "UPDATE `Control` SET `Control`.`Y` = '90' " +
    "WHERE `Control`.`Dialog_`='ExitDialog' AND `Control`.`Control`='Description'";
view = database.OpenView(sql);
view.Execute();
view.Close();

// The progressbar is too close to the status text on the Progress dialog. 
// This step moves the progressbar down from Y=115 to Y=118, about 1/3 line. 
sql = "UPDATE `Control` SET `Control`.`Y` = '118' " +
    "WHERE `Control`.`Dialog_`='ProgressDlg' AND `Control`.`Control`='ProgressBar'";
view = database.OpenView(sql);
view.Execute();
view.Close();

// The StatusLabel and ActionText controls are too short on the Progress dialog,
// which means the bottom of the text is cut off.  This step
// increases the height from 10 to 16.
sql = "UPDATE `Control` SET `Control`.`Height` = '16' " +
    "WHERE `Control`.`Dialog_`='ProgressDlg' AND `Control`.`Control`='StatusLabel'";
view = database.OpenView(sql);
view.Execute();
view.Close();
sql = "UPDATE `Control` SET `Control`.`Height` = '16' " +
    "WHERE `Control`.`Dialog_`='ProgressDlg' AND `Control`.`Control`='ActionText'";
view = database.OpenView(sql);
view.Execute();
view.Close();

database.Commit();

使用Heat.exe砸碎脸和造成“史诗Pwnage”痛苦的大安装

扩展Si的和 Robert-P关于热的回答。 翻译: (使用heat可以避免手动将单个文件输入到项目中,并且可以自动化构建,从而使整个过程更容易。) 详细介绍WiX 2.0热语法

For newer versions (not all that different from older versions but there are potentially annoying syntax changes....) go to the directory Heat is in from the cmd.exe and just type in heat but I have a example one right here for help with newer versions if needed. Adding the following to your Build Event in visual studio 2010. (Right Click Project->Properties ->Build Events-> Pre-Build Events) $(WIX)bin\heat.exe" dir "$(EnviromentVariable)" -cg GroupVariable -gg -scom -sreg -sfrag - srd -dr INSTALLLOCATION -var env.LogicPath -out "$(FragmentDir)\FileName.wxs -gg Generates Guids when heat is run(as in when you execute the command above) -scom Dont grab "COM files" -sreg Dont grab "Registry Files" -sfrag Dont grab "Fragments" -srd Dont grab the "root Dir" dir dir indicates you want Heat to look in a folder "$(EnviromentVariable)" The name of the variable you would add to the Preprocessor variables in the (Right click project, Go to properties) project properties->Build section where it says Define preprocessor variables (assumes visual studio 2010) Example: EnviromentVariable=C:\Project\bin\Debug;No double quotes but end with a semicolon -cg GroupVariable The ComponentGroup that will be referenced from the fragment created to the main wxs file FragmentDir The fragment directory where the output wxs fragment will be stored FileName.wxs The the name of the file Full tutorial here, So freakin helpful Part 1 Part 2

设置IIS enable32BitAppOnWin64标志http://trycatchfail.com/blog/post/WiX-Snippet-change-enable32BitAppOnWin64.aspx

<InstallExecuteSequence>
   <RemoveExistingProducts After="InstallFinalize" />
   <Custom Action="ConfigureAppPool" After="InstallFinalize" >
     <![CDATA[NOT Installed AND VersionNT64 >= 600]]>         
   </Custom>
</InstallExecuteSequence>

<CustomAction Id="ConfigureAppPool" Return="check" Directory="TARGETDIR" ExeCommand="[SystemFolder]inetsrv\appcmd set apppool /apppool.name:[APPPOOLNAME] /enable32BitAppOnWin64:false" />